TROUBLESHOOTING TROUBLESHOOTING
PROBLEM POSSIBLE CAUSES WHAT TO DO
The machine is On but
ceases to operate
Turn machine Off. Wait
for 60 minutes and turn
machine back On.
If problem persists, call
Breville Customer Service
1-866-273-8455.
Steam pouring out of
group head
Turn machine Off. Wait
for 60 minutes and turn
machine back On.
If problem persists, call
Breville Customer Service
1-866-273-8455.
Espresso only drips from
the portafilter spouts,
restricted flow
Coffee is ground
too finely.
Use slightly coarser grind.
Too much coffee in the
filter basket.
Lower dose of coffee.
Coffee tamped too
firmly.
Tamp between 30-40lbs
or 15-20kg of pressure.
The filter basket may be
blocked.
Use the fine pin on the
provided cleaning tool
to clear the outlet hole(s)
on the under side of the
filter basket. If it continues
to be blocked, dissolve a
cleaning tablet in hot water
and soak filter basket and
portafilter in the solution
for approx. 20 minutes.
Rinse thoroughly.
Espresso runs out
too quickly
The coffee is ground
too coarse.
Use slightly finer grind.
Not enough coffee in
the filter basket.
Increase dose of coffee.
Coffee not tamped
firmly enough.
Tamp between 30-40lbs
or 15-20kg of pressure.
PROBLEM POSSIBLE CAUSES WHAT TO DO
Coffee not hot enough Cups not pre-heated. Rinse cups under hot water
outlet and place on cup
warming tray.
Milk not hot enough
(if making a cappuccino
or latte etc).
Heat milk until base of
the jug becomes hot
to touch.
Extraction temperature
is too low.
Increase extraction
temperature. See
‘Extraction Temperature’,
page 16.
No crema Coffee beans are stale. Buy freshly roasted coffee
with a “roasted on” date.
Using Single Wall
Filter Baskets with
pre-ground coffee.
Ensure you use Dual Wall
Filter Baskets with
pre-ground coffee.
Espresso runs out
around the edge of the
portafilter.
Portafilter not inserted in
the group head correctly
Ensure portafilter is
inserted and rotated until
resistance is felt.
There are coffee
grounds around the
filter basket rim.
Clean excess coffee from
the rim of the filter basket
to ensure a proper seal in
group head.
Too much coffee in the
filter basket.
Ensure upper edge of the
metal cap on the tamper
is level with the rim of the
filter basket after tamping.
Unable to set Auto
Start time
Clock not set. Set clock.
E1, E2 or E3 error
message on LCD screen
An error that cannot
be reset by the user
has occurred.
Call Breville Customer